Technical data |
AX5801-0200 |
---|---|
Operating voltage of the relays |
24 V DC (-15 %/+20 %) |
Operating voltage of the feedback contacts |
24 V DC (-15 %/+20 %) |
Max. switching current of the feedback contacts |
0.35 A |
Cross-section of the connections (use of ferrules is recommended) |
0.2…1.5 mm² |
Stripping length of the wires |
10 mm |
Current consumption (total for both relays) |
50 mA |
Protocol |
– |
Fault response time |
– |
Weight |
approx. 85 g |
Ambient temperature (operation) |
see documentation |
Storage temperature |
-25…+70 °C |
Permissible humidity |
5…95 %, non-condensing |
Further environmental and operating conditions |
see AX5000 |
Realisation STO |
hard-wired via safe inputs |
Safe stop functions |
Safe Torque Off (STO), Safe Operating Stop (SOS), Safe Stop 1 (SS1), Safe Stop 2 (SS2) |
Safety standard |
ISO 13849-1:2006 (Cat. 4, PL e) and IEC 61508 (ed.2) (SIL 3) |